PCA9665_2 © NXP B.V. 2006. All rights reserved.
Product data sheet Rev. 02 — 7 December 2006 44 of 91
NXP Semiconductors
PCA9665
Fm+ parallel bus to I
2
C-bus controller
E8h Previouslyaddressed
with General Call;
BC[6:0] data bytes
have been received;
ACK has been
returned for all the
bytes, except for the
last one where NACK
bit has been returned
Read data bytes
or
X X 0 X 0 0 1 Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1
Read data bytes
or
X X 0 X 0 1 1 Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1
Read data bytes
or
X X 1 X 0 0 1 Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
Read data bytes X X 1 X 0 1 1 Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
A0h A STOP condition or
repeated START
condition has been
received while still
addressed as slave
receiver
No I2CDAT action
or
X X 0 X 0 0 1 Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1
No I2CDAT action
or
X X 0 X 0 1 1 Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1
No I2CDAT action
or
X X 1 X 0 0 1 Switched to not addressed slave mode;
No recognition of own slave address;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
No I2CDAT action X X 1 X 0 1 1 Switched to not addressed slave mode;
Own slave address will be recognized;
General Call address will be recognized if GC = 1;
A START condition will be transmitted when the
bus becomes free.
Table 40. Slave Receiver Buffered mode (MODE = 1)
…continued
Status
code
(I2CSTA)
Status of the
I
2
C-bus and the
PCA9665
Application software response Next action taken by the PCA9665
To/from I2CDAT To/from I2CCOUNT To I2CCON
LB BC[6:0] STA STO SI AA MODE